$119,995.00
Inc. GST. Delivery is free within 50 km of a capital city centre, with a distance band beyond. Plugs into a standard 240 V outlet.
Order now for delivery in January 2027.
Add White Glove Installation for $2,500 with the Installation option. It is not included in the product price.
Norge H-02 Hasee Hyperbaric Chamber
A hard shell hyperbaric chamber in a nickel-steel alloy body, adjustable from 1.1 to 2.0 ATA, with a dedicated oxygen main unit. Full-body red light and an in-seat leg massager are built into the cabin. Double or single seat, black or white.
Pressure and oxygen
Anywhere from 1.1 to 2.0 ATA.
Set the target pressure on either touchscreen. The chamber pressurises, holds and brings you down in a controlled descent, while the main unit delivers 93 percent oxygen at 10 or 20 litres per minute. Triple relief valves and an internal emergency vent are standard.

The cabin
Two seats or one.
The same nickel-steel shell, oxygen system and in-cabin red light in both. Three-sided panoramic windows and a wide upward-sliding hatch keep the chamber open and bright. Inside, a zero-gravity electric sofa with an in-seat leg massager, humidity held near 26 percent and under 20 dB of noise.
-
Double
1780 x 1352 x 1808 mm, 620 kg.
-
Single
1780 x 984 x 1990 mm, 560 kg.
Control
Set it from inside or out.
Dual touchscreens
One inside the chamber and one on the shell. Set the target pressure, oxygen flow and session length, and follow pressurisation, hold and controlled descent on screen.
A safe way out. Triple relief valves and an emergency vent for safe, rapid exit.
The main unit
Two parts, one system.
The chamber sits on rollers, and a separate concentrator and compressor delivers the oxygen, so the chamber itself stays quiet and cool. Three facts about the system.
- 93 percent oxygen
- At 10 or 20 litres per minute, selectable on the touchscreen.
- 5 micron filtration
- With negative ion output from the main unit.
- 63 dB outside, under 20 dB inside
- The main unit is rated at 1500 W and runs from a standard 10 A outlet.
Where it goes
At home, in a studio or a clinic.
Indoors on a level, dry floor rated for 560 to 620 kg, with ground floor or lift access, clear space for the hatch to slide open and about 600 mm around the main unit.
-
At home
-
Studio or clinic
Plan one outlet per chamber.
Delivery and install
Nothing to wire.
Your room
A level, dry indoor floor, a room kept ventilated and between 10 and 30 °C, and a standard 240 V, 10 A outlet with RCD protection within reach of the main unit. No electrician is needed for a compliant outlet.
Norge. Delivery is free within 50 km of a capital city centre and banded by distance beyond. With White Glove Installation, $2,500, our team positions the chamber on its rollers, connects the main unit, runs a full pressure test and walks you through the touchscreens, equalisation and emergency venting.
Specification
Specification
The Norge Hasee, figure by figure.
The chamber 15
- Type
- Hard shell hyperbaric chamber with a zero-gravity sofa
- Mobility
- Chamber on rollers
- Capacity
- Double: 2 people. Single: 1 person
- Shell
- Nickel-steel alloy, three-sided panoramic windows, upward-sliding hatch
- Pressure
- Adjustable from 1.1 to 2.0 ATA
- Oxygen
- 93 percent at 10 or 20 L/min
- Filtration
- 5 micron, negative ion output
- Interior
- Zero-gravity electric sofa, in-seat leg massager (15 to 30 W), full-body red light
- Humidity
- Held near 26 percent
- Noise
- 63 dB outside, under 20 dB inside
- Control
- Dual touchscreens, inside and outside, on a sculpted Norge console
- Safety
- Triple relief valves, internal emergency vent
- Mask
- Ready for an optional BIBS mask
- Finish
- Black or White
- Compliance
- CE
Size, power and delivery 8
- Chamber size
- Double 1780 x 1352 x 1808 mm, 620 kg. Single 1780 x 984 x 1990 mm, 560 kg
- Main unit
- Oxygen concentrator and compressor, 1500 W rated
- Power
- 240 V single phase, 50 Hz, standard 10 A outlet with RCD protection, Australian 3-pin plug
- Room
- Level, dry indoor floor rated for the chamber weight, ground floor or lift access, ventilated, 10 to 30 °C
- Clearance
- Space for the hatch to slide open, about 600 mm around the main unit
- Delivery
- Free within 50 km of a capital city centre; distance bands beyond, shown at checkout
- Installation
- White Glove Installation, $2,500: placed, connected, pressure tested and commissioned by Norge
- Warranty
- Norge product warranty on the chamber shell, main unit and controls from delivery; documentation on request
Questions
Asked before buying
What is included in the price?
The hard shell chamber and main unit, full-body red light in the cabin, the zero-gravity sofa with leg massager, dual touchscreens, and the Norge product warranty. White Glove Installation is $2,500 and covers placement and connection, a full pressure test and commissioning. Double $119,995, single $99,995, both including GST. Delivery is free within 50 km of a capital city centre; beyond that, a distance band is shown at checkout.
Do I need an electrician?
No. The main unit plugs into a standard 240 V, 10 A Australian outlet protected by an RCD safety switch, straight into the wall, not a power board or extension lead. If your outlet has no RCD protection, or the circuit is at or near capacity, have an electrician assess the supply before delivery.
What does the room need?
A level, dry indoor floor rated for the chamber weight (560 kg single, 620 kg double), with ground floor or lift access. Clear space for the hatch to slide open and about 600 mm around the main unit so it can breathe. A room kept ventilated and between 10 and 30 °C, and an access route that fits the chamber through doors, stairs or lifts: double 1780 x 1352 x 1808 mm, single 1780 x 984 x 1990 mm. Any building, strata or premises approvals are arranged by you.
When can I use it?
As soon as commissioning is complete. Our team positions the chamber, connects the main unit, runs a full pressure test and walks you through the controls, ear equalisation and how to exit before handover.
Can a studio run more than one?
Yes. Plan one outlet per chamber, and if the circuit is at or near capacity, have an electrician assess the supply before delivery.
How long is a session?
The product guide suggests sessions of 45 to 90 minutes, at pressures from 1.1 to 2.0 ATA. Suggested usage only: follow the user manual and the advice of your health professional.
What can I take into the chamber?
The chamber is an oxygen-enriched environment. No open flames, smoking, oils, petroleum-based products or battery devices that are not approved for oxygen-enriched environments may be taken inside. Never obstruct the relief valves or the main unit air intakes.
Should anyone check before using it?
Consult a medical professional before use if you are pregnant, have a lung condition, a history of pneumothorax, or any implanted device. You must equalise your ears during pressurisation, and should not use the chamber with a cold, sinus or ear infection.
Does it treat medical conditions?
No. The Norge Hasee is not intended to diagnose, treat, cure or prevent any disease, and Norge does not provide medical advice. Results vary between people and depend on pressure, session length and consistency of use.
What is the warranty?
A Norge product warranty covers the chamber shell, main unit and controls from the date of delivery. Full warranty documentation is available on request and forms part of your purchase agreement. It operates in addition to your rights under the Australian Consumer Law.